finestheader
Finest Instrument Corporation  
   
  • A 25 Mega-sample/Second (one channel minimum) sample rate for rapid data updates.
  • Lab scope signal patterns.
  • True RMS Graphing Multimeter (GMM) measurements and graphs.
  • OBD II (EOBD) Code Reader function.
  • A unique "Glitch Snare" mode which captures, displays and optionally saves abnormal signal patterns in the Scope mode of the COMPONENT TESTS only when they occur.
  • Preset tests that enable the user to check the majority of automotive sensors, actuators and systems easily and quickly.
  • Powerful built-in reference information for each preset test which includes a test procedure showing how to connect to the circuit, a normal reference signal pattern, theory of operation and troubleshooting tips.
  • Menu-driven interface has automatic configurations for most of non-preset tests, so you will find that the instrument is easy-to-use.
  • The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage.
  • The Diesel function allows you to set injection pump timing and RPM using the optional Diesel accessories.
USB interface supports updates for code and data.

1006 Automotive Scope / GMM / OBDII (EOBD) Code-Reader

 
1006 Scope Kit
 
Options
 
Options

SPECIFICATIONS

[ DSO ]

Horizontal

 

Sample rate

:

25 Mega sample/second

Record length

:

1000 Points

Update rate

:

Real time, Roll

Accuracy

:

± (0.1% + 1 pixel)

Sweep rate

:

1 µs to 50 sec in a 1, 2, 5 sequence
(Scope mode)
5 s to 24 Hours in a 1, 2, 5 sequence
(GMM mode)

Vertical

 

Band width

:

DC to 5 MHz ; -3 dB

Resolution

:

8 bit

Channel

:

2 Channel

Coupling

:

AC, DC, GND

Input Impedance

:

1 Mohm / 70 pF

Maximum Input Voltage

:

300 V

Volt/Division

:

50 mV to 100 V in a 1, 2, 5 sequence

Accuracy

:

± 3 %

Trigger

 

Trigger Source

:

CH A, CH B, TRIGGER (External trigger)

Sensitivity (CH A)

:

< 1.0 div to 5 MHz

Sensitivity (Trigger)

:

0.2 V p-p

Modes

:

Single shot, Normal, Auto

Coupling

:

AC, DC

Slope

:

Rising and falling edge

Others

 

Glitch Snare

:

SCOPE Mode (Component Test only)

Acquire Mode

:

SCOPE Mode

Setup memory

:

8 Waveform & Setup

Reference waveform

:

51 Waveform and Setup

Cursor

:

Time and Volt

Instrument Setup

:

Language, Contrast, Graticule

[ GMM ]

    RPM Measurement

Mode

Range

Accuracy

4 cylinder

120 - 20000 RPM

2 RPM

2 cylinder

60 - 10000 RPM


    Frequency Measurement

Function

Range

Resolution

Accuracy

Frequency

10 Hz

0.001 Hz

± (0.1 % + 3 d)

100 Hz

0.01 Hz

1 kHz

0.1 Hz

10 kHz

1 Hz

100 kHz

10 Hz

1 MHz

100 Hz

5 MHz

1 kHz

% Duty

2.0 % ~ 98 %

0.1 %

Pulse Width > 2 µs

Dwell

3.6 ° ~ 356.4 °

0.1 °

1.2 °/krpm + 2 d

Pulse Width

2 µs ~ 450 ms (Pulse Width > 2 µs)


    DC Voltage Measurement

Range

Resolution

Accuracy

500 mV

0.1 mV

± (0.3 % + 5 d)

5 V

0.001 V

50 V

0.01 V

600 V

0.1 V

     Input Impedance : 10 MΩ


    AC Voltage Measurement

Range

Resolution

Accuracy

40 Hz ~ 400 Hz

400 Hz ~ 10 kHz

500 mV

0.1 mV

± (0.5 % + 5 d)

± (2.5 % + 5 d)

5 V

0.001 V

50 V

0.01 V

600 V

0.1 V

     Input Impedance : 10 MΩ


    (AC+DC) Voltage Measurement

Range

Resolution

Accuracy

40 Hz ~ 400 Hz

400 Hz ~ 10 kHz

DC 500 mV

0.1 mV

± (0.8 % + 5 d)

± (3.0 % + 5 d)

DC 5 V

0.001 V

DC 50 V

0.01 V

DC 600 V

0.1 V


    Ohm Measurement

Range

Resolution

Accuracy

500 Ω

0.1 Ω

± (0.5 % + 5 d)

5 kΩ

0.001 kΩ

50 kΩ

0.01 kΩ

500 kΩ

0.1 kΩ

5 MΩ

0.001 MΩ

± (0.75 % + 5 d)

30 MΩ

0.01 MΩ

± (0.75 % + 10 d)


    Continuity Test

Test Voltage

Threshold

Response time

1.2 V

Approx. 70 Ω

1 ms


    Diode Test

Range

Open Circuit Voltage

Accuracy

2.0 V

3.0 V

± (2.0 % + 5 d)


    Temperature Measurement

Range

Resolution

Accuracy

-50 °C to 1300 °C

0.1 °C

± 3 °C

-58 °F to 2372 °F

0.1 °F

± 5.4 °F


    DC Ampere Measurement (Current Probe Output)

Range

Resolution

Accuracy

30 mA ~ 20 A

1 mV/10 mA

± (1.5 % + 20 mA)

100 mA ~ 40 A

1 mV/100 mA

± (2.0 % + 20 mA)

40 A ~ 60 A

1 mV/100 mA

± (4.0 % + 0.3 A)


    AC Ampere Measurement (Current Probe Output)

Range

Resolution

Accuracy

40 Hz ~ 1 kHz

1 kHz ~ 5 kHz

30 mA ~ 10 A

1 mV/10 mA

± (2.0 % + 20 mA)

± (4.0 % + 30 mA)

100 mA ~ 40 A

1 mV/100 mA

± (2.0 % + 20 mA)

± (6.0 % + 30 mA)

40 A ~ 60 A

1 mV/100 mA

± (8.0 % + 0.3 A)

<< Back to Products   I   << Finest 1005 Automotive scope