SPECIFICATIONS |
[ DSO ]
| Horizontal |
|
Sample rate |
: |
25 Mega sample/second |
Record length |
: |
1000 Points |
Update rate |
: |
Real time, Roll |
Accuracy |
: |
± (0.1% + 1 pixel) |
Sweep rate |
: |
1 µs to 50 sec in a 1, 2, 5 sequence
(Scope mode)
5 s to 24 Hours in a 1, 2, 5 sequence
(GMM mode) |
Vertical |
|
Band width |
: |
DC to 5 MHz ; -3 dB |
Resolution |
: |
8 bit |
Channel |
: |
2 Channel |
Coupling |
: |
AC, DC, GND |
Input Impedance |
: |
1 Mohm / 70 pF |
Maximum Input Voltage |
: |
300 V |
Volt/Division |
: |
50 mV to 100 V in a 1, 2, 5 sequence |
Accuracy |
: |
± 3 % |
Trigger |
|
Trigger Source |
: |
CH A, CH B, TRIGGER (External trigger) |
Sensitivity (CH A) |
: |
< 1.0 div to 5 MHz |
Sensitivity (Trigger) |
: |
0.2 V p-p |
Modes |
: |
Single shot, Normal, Auto |
Coupling |
: |
AC, DC |
Slope |
: |
Rising and falling edge |
Others |
|
Glitch Snare |
: |
SCOPE Mode (Component Test only) |
Acquire Mode |
: |
SCOPE Mode |
Setup memory |
: |
8 Waveform & Setup |
Reference waveform |
: |
51 Waveform and Setup |
Cursor |
: |
Time and Volt |
Instrument Setup |
: |
Language, Contrast, Graticule |
|
[ GMM ] |
RPM Measurement
| Mode |
Range |
Accuracy |
4 cylinder |
120 - 20000 RPM |
2 RPM |
2 cylinder |
60 - 10000 RPM |
|
Frequency Measurement
| Function |
Range |
Resolution |
Accuracy |
Frequency |
10 Hz |
0.001 Hz |
± (0.1 % + 3 d) |
100 Hz |
0.01 Hz |
1 kHz |
0.1 Hz |
10 kHz |
1 Hz |
100 kHz |
10 Hz |
1 MHz |
100 Hz |
5 MHz |
1 kHz |
% Duty |
2.0 % ~ 98 % |
0.1 % |
Pulse Width > 2 µs |
Dwell |
3.6 ° ~ 356.4 ° |
0.1 ° |
1.2 °/krpm + 2 d |
Pulse Width |
2 µs ~ 450 ms (Pulse Width > 2 µs) |
|
DC Voltage Measurement
| Range |
Resolution |
Accuracy |
500 mV |
0.1 mV |
± (0.3 % + 5 d) |
5 V |
0.001 V |
50 V |
0.01 V |
600 V |
0.1 V |
|
Input Impedance : 10 MΩ |
AC Voltage Measurement
| Range |
Resolution |
Accuracy |
40 Hz ~ 400 Hz |
400 Hz ~ 10 kHz |
500 mV |
0.1 mV |
± (0.5 % + 5 d) |
± (2.5 % + 5 d) |
5 V |
0.001 V |
50 V |
0.01 V |
600 V |
0.1 V |
|
Input Impedance : 10 MΩ |
(AC+DC) Voltage Measurement
| Range |
Resolution |
Accuracy |
40 Hz ~ 400 Hz |
400 Hz ~ 10 kHz |
DC 500 mV |
0.1 mV |
± (0.8 % + 5 d) |
± (3.0 % + 5 d) |
DC 5 V |
0.001 V |
DC 50 V |
0.01 V |
DC 600 V |
0.1 V |
|
Ohm Measurement
| Range |
Resolution |
Accuracy |
500 Ω |
0.1 Ω |
± (0.5 % + 5 d) |
5 kΩ |
0.001 kΩ |
50 kΩ |
0.01 kΩ |
500 kΩ |
0.1 kΩ |
5 MΩ |
0.001 MΩ |
± (0.75 % + 5 d) |
30 MΩ |
0.01 MΩ |
± (0.75 % + 10 d) |
|
Continuity Test
| Test Voltage |
Threshold |
Response time |
1.2 V |
Approx. 70 Ω |
1 ms |
|
Diode Test
| Range |
Open Circuit Voltage |
Accuracy |
2.0 V |
3.0 V |
± (2.0 % + 5 d) |
|
Temperature Measurement
| Range |
Resolution |
Accuracy |
-50 °C to 1300 °C |
0.1 °C |
± 3 °C |
-58 °F to 2372 °F |
0.1 °F |
± 5.4 °F |
|
DC Ampere Measurement (Current Probe Output)
| Range |
Resolution |
Accuracy |
30 mA ~ 20 A |
1 mV/10 mA |
± (1.5 % + 20 mA) |
100 mA ~ 40 A |
1 mV/100 mA |
± (2.0 % + 20 mA) |
40 A ~ 60 A |
1 mV/100 mA |
± (4.0 % + 0.3 A) |
|
AC Ampere Measurement (Current Probe Output)
| Range |
Resolution |
Accuracy |
40 Hz ~ 1 kHz |
1 kHz ~ 5 kHz |
30 mA ~ 10 A |
1 mV/10 mA |
± (2.0 % + 20 mA) |
± (4.0 % + 30 mA) |
100 mA ~ 40 A |
1 mV/100 mA |
± (2.0 % + 20 mA) |
± (6.0 % + 30 mA) |
40 A ~ 60 A |
1 mV/100 mA |
± (8.0 % + 0.3 A) |
|